The TCF-142 media converters are equipped with a multiple interface circuit that can handle RS-232 or RS-422/485 serial interfaces and multi-mode or single-mode fiber. TCF-142 converters are used to extend serial transmission up to 5 km (TCF-142-M with multi-mode fiber) or up to 40 km (TCF-142-S with single-mode fiber). The TCF-142 converters can be configured to convert either RS-232 signals, or RS-422/485 signals, but not both at the same time.
The TCF-142 converters can automatically detect the serial baudrate, which is an extremely convenient feature. Even if a device’s baudrate is changed, the signal will still be transmitted through the media converter without any data loss.
The TCF-142 converters can be used to connect serial devices to a fiber ring. To form the ring, connect the Tx port of one TCF-142 to the Rx port of a neighboring converter. Once the ring is set up, simply use the DIP switches to configure the TCF-142 converters for ring mode. When one node transmits a signal, the signal travels around the ring until it returns back to the transmitting unit, which then blocks the signal. With the TCF-142, you can set up fiber rings that have a total circumference of up to 100 km.
ADDC® is a patented hardware data flow solution developed by Moxa to handle RS-485 data direction control. ADDC® senses and controls RS-485 data direction automatically, making it unnecessary to use the handshaking signal.
Serial Interface | |
No. of Ports | 2 |
Serial Standards | RS-232, RS-422, RS-485 |
Baudrate | 50 bps to 921.6 kbps (supports non-standard baudrates) |
Flow Control | ADDC® (automatic data direction control) for RS-485 |
Optical Fiber | Read more |
Pull High/Low Resistor for RS-485 | 1 kilo-ohm, 150 kilo-ohms |
RS-485 Data Direction Control | ADDC® (automatic data direction control) |
Terminator for RS-485 | N/A, 120 ohms, 120 kilo-ohms |
Connector | 7-pin terminal block |
Latency | 300 ns |
Serial Signals | |
RS-232 | TxD, RxD, GND |
RS-422 | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | Data+, Data-, GND |
Power Parameters | |
No. of Power Inputs | 1 |
Input Current | 70 to 140 mA @ 12 to 48 VDC |
Input Voltage | 12 to 48 VDC |
Overload Current Protection | Supported |
Power Connector | Terminal block |
Power Consumption | 70 to 140 mA @ 12 to 48 VDC |
Physical Characteristics | |
IP Rating | IP30 |
Housing | Metal |
Dimensions (with ears) | 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in) |
Dimensions (without ears) | 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in) |
Weight | 320 g (0.71 lb) |
Installation | Wall mounting |
Environmental Limits | |
Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 1 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 3 V IEC 61000-4-8 PFMF |
Environmental Testing | IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3 |
Safety | EN 60950-1, IEC 60950-1 |
Vibration | IEC 60068-2-6 |
MTBF | |
Time | 780,480 hrs |
Standards | Telcordia (Bellcore), GB |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Name | Type | Version | Release Date | |
Datasheet for TCF-142 Series | Datasheet | V1.2 | 21 May 2020 |
Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/english/productview.php on line 615