The PTC-101 Ethernet-to-fiber media converters convert from 10/100BaseT(X) to 100BaseFX. Models are available with either SC, ST, or LC connectors. The PTC-101 converters eliminate the need for additional wiring, and support IEEE 802.3 and IEEE 802.3u/x protocols with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet networks. The PTC-101 is compliant with mandatory sections of IEC 61850-3, covering operating temperature, power input voltage, surge, ESD, and vibration, as well as conformal coating and power insulation, making the media converters suitable for a variety of industrial applications.
Ethernet Interface | |
10/100BaseT(X) Ports (RJ45 connector) | 1 |
100BaseFX Ports (multi-mode SC connector) | PTC-101-M-SC-HV/M-SC-LV: 1 |
100BaseFX Ports (multi-mode ST connector) | PTC-101-M-ST-HV/M-ST-LV: 1 |
100BaseFX Ports (single-mode SC connector) | PTC-101-S-SC-HV/S-SC-LV: 1 |
100BaseFX Ports (single-mode ST connector) | PTC-101-S-ST-HV/S-ST-LV: 1 |
100BaseFX Ports (multi-mode LC connector) | PTC-101-M-LC-HV/M-LC-LV: 1 |
100BaseFX Ports (single-mode LC connector) | PTC-101-S-LC-HV/S-LC-LV: 1 |
Magnetic Isolation Protection | 1.5 kV (built-in) |
Optical Fiber | Read more |
Power Parameters | |
Input Voltage | LV-DC models: 20 to 72 VDC HV-AC models: 100 to 240 VAC HV-DC models: 88 to 300 VDC |
Input Current | LV-DC models: 150 mA @ 20 to 72 VDC HV-AC models: 200 to 350 mA @ 100 to 240 VAC HV-DC models: 47 mA @ 88 VDC |
Overload Current Protection | Supported |
Power Consumption | LV-DC models: 150 mA @ 20 to 72 VDC HV-AC models: 200 to 350 mA @ 100 to 240 VAC HV-DC models: 47 mA @ 88 VDC |
Physical Characteristics | |
Housing | Metal |
Dimensions | 152.15 x 126.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
Weight | Packaged: 875 g (1.92 lb) Product only: 690 g (1.52 lb) |
Installation | DIN-rail mounting |
Environmental Limits | |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs |
Environmental Testing | IEC 60068-2-1 IEC 60068-2-14 IEC 60068-2-2 IEC 60068-2-3 |
Safety | EN 60950-1, UL 60950-1 |
Vibration | IEC 60068-2-6 |
Power Substation | IEC 61850-3 |
MTBF | |
Time | 1,211,613 hrs |
Standards | MIL-HDBK-217F |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Name | Type | Version | Release Date | |
Datasheet for PTC-101 Series | Datasheet | V1.3 | 21 May 2020 |