Login   |  
Notice: Undefined index: basket in /opt/lampp/htdocs/english/menutop.php on line 14
(0)   |  

TEL. & FAX +66(0)2-020-3301

MGate 5118 Series

Home  >   MOXA  >   Industrial Edge Connectivity  >  
Protocol Gateways  >   Modbus TCP Gateways

1-port CAN-J1939 to Modbus/PROFINET/EtherNet/IP gateways

Product Feature

  • Converts J1939 to Modbus, PROFINET, or EtherNet/IP
  • Supports Modbus RTU/ASCII/TCP master/client and slave/server
  • Supports EtherNet/IP Adapter
  • Supports PROFINET IO device
  • Supports J1939 protocol
  • Effortless configuration via web-based wizard
  • Built-in Ethernet cascading for easy wiring
  • Embedded traffic monitoring/diagnostic information for easy troubleshooting
  • microSD card for configuration backup/duplication and event logs
  • Status monitoring and fault protection for easy maintenance
  • CAN bus and serial port with 2 kV isolation protection
  • -40 to 75°C wide operating temperature models available
  • Security features based on IEC 62443

Introduction

The MGate 5118 industrial protocol gateways support the SAE J1939 protocol, which is based on CAN bus (Controller Area Network). SAE J1939 is used to implement communication and diagnostics among vehicle components, diesel engine generators, and compression engines, and is suitable for the heavy-duty truck industry and backup power systems. It is now common to use an engine control unit (ECU) to control these kinds of devices, and more and more applications are using PLCs for process automation to monitor the status of J1939 devices connected behind the ECU.

The MGate 5118 gateways support the conversion of J1939 data to Modbus RTU/ASCII/TCP, EtherNet/IP, or PROFINET protocols to support most PLC applications. Devices that support the J1939 protocol can be monitored and controlled by PLCs and SCADA systems that use the Modbus RTU/ASCII/TCP, EtherNet/IP, and PROFINET protocols. With the MGate 5118, you can use the same gateway in a variety of PLC environments.

 

Key-in-Free J1939 Command

The J1939 protocol is designed to retrieve a wide range of data from CAN-J1939 devices. To eliminate the need to key in all J1939 commands into the gateway by hand, MGate 5118 gateways can auto detect the output commands used by the CAN device.

With a single click in the web console, all of the output commands from your CAN device will be detected by the gateway automatically. The commands will be displayed in the web console’s command list, and then can be further modified by the user if needed. The MGate 5118 gateways make it much easier for users to connect PLCs with CAN devices.

 

A Variety of Maintenance Functions

The MGate 5118 gateways support a web console for easy configuration and maintenance, and the built-in traffic monitor function monitors J1939 protocol traffic, allowing users to monitor the status of connected CAN devices, including error count, packet count, and bus-offline. The traffic monitor function can also be used to troubleshoot CAN devices. The diagnostics tool helps users to check CAN device settings and indicates CAN device availability by reading the J1939 network address. In addition, the MGate 5118 gateways have a built-in Live List function for when two or more J1939 devices are connected to the same CAN bus. This function shows the PGN and address of packets transmitted from each device, giving users the ability to gage the loading of the CAN bus.

To detect loose cables, the MGate 5118 gateways support status monitoring and fault protection functions. The status monitoring function notifies a PLC when the cable between the gateway and CAN device is loose. In addition, the fault protection function executes actions predefined by the user when the cable between the gateway and PLC is loose.

Ethernet Interface

10/100BaseT(X) Ports (RJ45
connector)
2
Auto MDI/MDI-X connection
Magnetic Isolation Protection1.5 kV (built-in)

Ethernet Software Features

Industrial ProtocolsModbus TCP Client (Master), Modbus TCP Server (Slave), PROFINET IO
Device, EtherNet/IP Scanner, EtherNet/IP Adapter
Configuration OptionsWeb Console (HTTP/HTTPS), Device Search Utility (DSU), Telnet Console
ManagementARP, DHCP Client, DNS, HTTP, HTTPS, SMTP, SNMP Trap, SNMPv1/v2c/v3,
TCP/IP, Telnet, SSH, UDP, NTP Client
MIBRFC1213, RFC1317
Time ManagementNTP Client

Serial Interface

Console PortRS-232 (TxD, RxD, GND), 8-pin RJ45 (115200, n, 8, 1)
No. of Ports1
ConnectorDB9 male
Serial StandardsRS-232/422/485
Baudrate50 bps to 921.6 kbps
Data Bits7, 8
ParityNone, Even, Odd, Space, Mark
Stop Bits1, 2
Flow ControlRTS Toggle (RS-232 only), RTS/CTS
RS-485 Data Direction ControlADDC® (automatic data direction control)
Pull High/Low Resistor for RS-4851 kilo-ohm, 150 kilo-ohms
Terminator for RS-485120 ohms
Isolation2 kV (built-in)

Serial Signals

RS-232TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422Tx+, Tx-, Rx+, Rx-, GND
RS-485-2wData+, Data-, GND
RS-485-4wTx+, Tx-, Rx+, Rx-, GND

Serial Software Features

Configuration OptionsSerial Console
Industrial ProtocolsJ1939, Modbus RTU/ASCII Master, Modbus RTU/ASCII Slave

Modbus RTU/ASCII

ModeMaster, Slave
Functions Supported1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Commands128

Modbus TCP

ModeClient (Master), Server (Slave)
Functions Supported1, 2, 3, 4, 5, 6, 15, 16, 23
Max. No. of Client Connections16
Max. No. of Server Connections32
Max. No. of Commands128

PROFINET

ModeIO Device
Max. No. of IO Controller
Connections
1 (for read/write)
Input Data Size512 bytes
Output Data Size512 bytes

EtherNet/IP

ModeScanner, Adapter
CIP Objects SupportedIdentity, Message Router, Assembly, Connection Manager, TCP/IP interface,
Ethernet link, Port
Max. No. of Scanner Connections1 (for read-only), 1 (for read/write)
Max. No. of Adapter Connections4
Input Data Size496 bytes
Output Data Size496 bytes

CAN Interface

Industrial ProtocolsJ1939
No. of Ports
ConnectorSpring-type Euroblock terminal
Baudrate250 kbps, 500 kbps
Terminator120 ohms
Isolation2 kV (built-in)

J1939

Max. No. of Commands256
Input Data Size2048 bytes
Output Data Size2048 bytes

Memory

microSD SlotUp to 32 GB (SD 2.0 compatible)

Power Parameters

Input Voltage12 to 48 VDC
Input Current416 mA @ 12 VDC
Power ConnectorSpring-type Euroblock terminal

Relays

Contact Current RatingResistive load: 2 A @ 30 VDC

Physical Characteristics

HousingMetal
IP RatingIP30
Dimensions45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)
Weight589 g (1.30 lb)

Environmental Limits

Operating TemperatureMGate 5118: 0 to 60°C (32 to 140°F)
MGate 5118-T: -40 to 75°C (-40 to 167°F)
Storage Temperature (package
included)
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)

Standards and Certifications

SafetyEN 60950-1, UL 61010-2-201
EMCEN 61000-6-2/-6-4
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
Hazardous LocationsATEX, Class I Division 2, IECEx
FreefallIEC 60068-2-32
ShockIEC 60068-2-27
VibrationIEC 60068-2-6, IEC 60068-2-64

MTBF

Time727,873 hrs
StandardsTelcordia SR332

Warranty

Warranty Period5 years
DetailsSee www.moxa.com/warranty
Name Type Version Release Date
Datasheet for MGate 5118 Series Datasheet V1.0 12 November 2018

Notice: Undefined variable: rs5 in /opt/lampp/htdocs/english/productview.php on line 609

Notice: Trying to get property 'tab_ap' of non-object in /opt/lampp/htdocs/english/productview.php on line 609


Notice: Undefined variable: title_ap in /opt/lampp/htdocs/english/productview.php on line 614


Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/english/productview.php on line 615

PT AUTOMATION (THAILAND) CO.,LTD.

Monday - Friday : office hours 9.00 AM – 6.00 PM

EN
TH