Moxa’s ioLogik E2200 Series Ethernet Remote I/O is a PC-based data acquisition and control device that uses proactive, event-based reporting to control I/O devices and features the Click&Go programming interface. Unlike traditional PLCs, which are passive and must poll for data, Moxa’s ioLogik E2200 Series will, when paired with our MX-AOPC UA Server, communicate with SCADA systems using active messaging that is pushed to the server only when state changes or configured events occur. Additionally, the ioLogik E2200 features SNMP for communications and control using an NMS (Network Management System), allowing IT professionals to configure the device to push I/O status reports according to configured specifications. This report-by-exception approach, which is new to PC-based monitoring, requires far less bandwidth than traditional polling methods.
This device supports simple yet powerful Click&Go™ technology to configure event-driven reports and alarms delivered over email, TCP/UDP, or SNMP traps, giving you a powerful and effective tool for delivering timestamped status updates in real time.
With built-in Click&Go™ intelligence, this device can be configured for simple outputs paired up with simple input triggers without the need for a PC controller. This allows it to be configured to automatically report I/O events according to conditions specified by the user.
By using SNMP, IT engineers can configure the device to deliver alarms (traps) for specific I/O events, or use it to read or write directly to the I/O registers. For the strongest security, the device features SNMPv3, with authentication and encryption. With Moxa’s SNMP-capable I/O, even IT professionals can easily integrate industrial sensors and servos over an Ethernet backbone, and with its strong network management tools, it is ideal for a wide variety of industrial applications, including environmental monitoring, telecommunications, power production and delivery, and transportation.
When used with MX-AOPC UA Server, devices can use active push communications when communicating changes in state and/or events to a SCADA system. Unlike a polling system, when using a push architecture for communications with a SCADA system, messages will only be delivered when changes in state or configured events occur, resulting in higher accuracy and lower amounts of data that need to be transferred.
Control Logic | |
Language | Click&Go |
Input/Output Interface | |
Analog Input Channels | ioLogik E2240 Series: 8 ioLogik E2242 Series: 4 |
Analog Output Channels | ioLogik E2240 Series: 2 |
Configurable DIO Channels (by software) | ioLogik E2212 Series: 4 ioLogik E2242 Series: 12 |
Digital Input Channels | ioLogik E2210 Series: 12 ioLogik E2212 Series: 8 ioLogik E2214 Series: 6 |
Digital Output Channels | ioLogik E2210/E2212 Series: 8 ioLogik E2260/E2262 Series: 4 |
Relay Channels | ioLogik E2214 Series: 6 |
RTD Channels | ioLogik E2260 Series: 6 |
Thermocouple Channels | ioLogik E2262 Series: 8 |
Buttons | Reset button |
Isolation | 3k VDC or 2k Vrms |
Rotary Switch | 0 to 9 |
Digital Inputs | |
Connector | Screw-fastened Euroblock terminal |
Counter Frequency | 900 Hz |
Digital Filtering Time Interval | Software configurable |
Dry Contact | On: short to GND Off: open |
I/O Mode | DI or event counter |
Points per COM | ioLogik E2210 Series: 12 channels ioLogik E2212/E2242 Series: 6 channels ioLogik E2214 Series: 3 channels |
Sensor Type | ioLogik E2210 Series: Dry Contact and Wet Contact (NPN) ioLogik E2212/E2214/E2242 Series: Dry Contact and Wet Contact (NPN or PNP) |
Wet Contact (DI to GND) | On: 0 to 3 VDC Off: 10 to 30 VDC |
Digital Outputs | |
Connector | Screw-fastened Euroblock terminal |
Current Rating | 200 mA per channel |
I/O Mode | DO or pulse output |
I/O Type | Sink |
Over-Current Protection | 0.65 A per channel @ 25°C |
Over-Temperature Shutdown | 175°C (min.) |
Over-Voltage Protection | 45 VDC (typical) |
Pulse Output Frequency | 1 kHz |
DIO Output Leakage Current | 4.0 mA @ 24 VDC |
Relays | |
Connector | Screw-fastened Euroblock terminal |
Contact Current Rating | Inductive load: 2 A @ 30 VDC, 250 VAC, 110 VAC Resistive load: 5 A @ 30 VDC, 250 VAC, 110 VAC |
Contact Resistance | 100 milli-ohms (max.) |
Electrical Endurance | 100,000 operations @ 5 A resistive load |
Mechanical Endurance | 1,000,000 operations |
Minimum Permitted Load | 1 A @ 5 VDC |
Pulse Output Frequency | 0.3 Hz at rated load |
Type | Form A (N.O.) power relay |
I/O Mode | Relay or pulse output |
Note | Ambient humidity must be non-condensing and remain between 5 and 95%. The relays may malfunction when operating in high condensation environments below 0°C. |
Analog Inputs | |
Accuracy | ioLogik E2240/E2242: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ioLogik E2240-T/E2242-T: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ±0.5% FSR @ -40 to 75°C |
Connector | Screw-fastened Euroblock terminal |
I/O Mode | Voltage/Current |
I/O Type | Differential |
Input Impedance | ioLogik E2240 Series: 900 kilo-ohms (min.) ioLogik E2242 Series: 200 kilo-ohms (min.) |
Input Range | ioLogik E2240 Series: ±150 mV, ±500 mV, ±5 V, ±10 V, 0 to 20 mA, 4 to 20 mA ioLogik E2242 Series: ±150 mV, 0 to 150 mV, ±500 mV, 0 to 500 mV, ±5 V, 0 to 5 V, ±10 V, 0 to 10 V, 0 to 20 mA, 4 to 20 mA |
Resolution | 16 bits |
Sampling Rate | ioLogik E2240 Series: All Channels: 10 samples/sec for voltage; 6 samples/sec for current Per Channel: 1.25 samples/sec for voltage; 0.75 samples/sec for current Single channel: 1.25 samples/sec for voltage; 0.75 samples/sec for current ioLogik E2242 Series: All channels: 32 samples/sec Per channel: 8 samples/sec Single channel: 100 samples/sec |
Built-in Resistor for Current Input | 120 ohms |
Over-Voltage Protection | -25 to +30 VDC (power on) -35 to +35 VDC (power off) |
Analog Outputs | |
Accuracy | ioLogik E2240: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ioLogik E2240-T: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ±0.5% FSR @ -40 to 75°C |
Output Range | 0 to 10 VDC 4 to 20 mA |
Resolution | 12-bit |
Load (Current Mode) | Internal power: 250 ohms (max.) |
RTDs | |
Accuracy | ioLogik E2260: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ioLogik E2260-T: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ±0.5% FSR @ -40 to 75°C |
Connector | Screw-fastened Euroblock terminal |
Input Connection | 2- or 3-wire |
Input Impedance | 625 kilo-ohms (min.) |
Sensor Type | JPT100, JPT200, JPT500 (-200 to 640°C) JPT1000 (-200 to 350°C) NI100, NI200, NI500 (-60 to 250°C) NI1000 (-60 to 150°C) NI120 (-80 to 260°C) PT1000 (-200 to 350°C) PT50, PT100, PT200, PT500 (-200 to 850°C) Resistance of 310, 620, 1250, and 2200 ohms |
Resolution | 0.1°C or 0.1 ohms |
Sampling Rate | All channels: 12 samples/sec Per channel: 2 samples/sec |
Thermocouples | |
Millivolt Accuracy | ioLogik E2262: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ioLogik E2262-T: ±0.1% FSR @ 25°C ±0.3% FSR @ -10 to 60°C ±0.5% FSR @ -40 to 75°C |
TC Accuracy | Types J, T, E, S, B: ±5°C Types K, R, N: ±8°C |
CJC Accuracy | ±0.5°C @ 25°C ±1.5°C @ -40 to 75°C |
Connector | Screw-fastened Euroblock terminal |
Input Impedance | 1 mega-ohms (min.) |
Millivolt Type | ±19.532 mV ±39.062 mV ±78.126 mV Fault and over-voltage protection: -35 to +35 VDC (power off); -25 to +30 VDC (power on) |
Resolution | 16 bits |
Sampling Rate | All channels: 12 samples/sec Per channel: 1.5 samples/sec |
Sensor Type | J, K, T, E, R, S, B, N |
LED Interface | |
LED Indicators | PWR, RDY, Serial, I/O Status |
Ethernet Interface | |
10/100BaseT(X) Ports (RJ45 connector) | 1 |
Magnetic Isolation Protection | 1.5 kV (built-in) |
Ethernet Software Features | |
Configuration Options | Web Console (HTTP), Windows Utility (ioAdmin) |
Industrial Protocols | CGI commands, Modbus TCP Server (Slave), Moxa AOPC (Active Tag), MXIO Library, SNMPv1 Trap, SNMPv1/v2c/v3 |
Management | BOOTP, IPv4, SMTP, DHCP Client, HTTP, TCP/IP |
MIB | Device Settings MIB |
Time Management | SNTP |
Modbus TCP | |
Functions Supported | 1, 2, 3, 4, 5, 6, 15, 16 |
Mode | Server (Slave) |
Serial Interface | |
Connector | Terminal block |
Serial Standards | RS-485 |
No. of Ports | 1 |
Baudrate | 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
Parity | None |
Data Bits | 8 |
Stop Bits | 1 |
Flow Control | None |
Serial Signals | |
RS-485-2w | Data+, Data-, GND |
Serial Software Features | |
Industrial Protocols | Modbus RTU Server (Client) |
Power Parameters | |
Power Connector | Screw-fastened Euroblock terminal |
No. of Power Inputs | 1 |
Input Voltage | 12 to 36 VDC |
Power Consumption | ioLogik E2210 Series: 202 mA @ 24 VDC ioLogik E2212 Series: 136 mA @ 24 VDC ioLogik E2214 Series: 170 mA @ 24 VDC ioLogik E2240 Series: 198 mA @ 24 VDC ioLogik E2242 Series: 178 mA @ 24 VDC ioLogik E2260 Series: 95 mA @ 24 VDC ioLogik E2262 Series: 160 mA @ 24 VDC |
Physical Characteristics | |
Dimensions | 115 x 79 x 45.6 mm (4.53 x 3.11 x 1.80 in) |
Weight | 250 g (0.55 lb) |
Installation | DIN-rail mounting, Wall mounting |
Wiring | I/O cable, 16 to 26 AWG Power cable, 16 to 26 AWG |
Housing | Plastic |
Environmental Limits | |
Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Altitude | 2000 m |
Standards and Certifications | |
Freefall | IEC 60068-2-32 |
EMC | EN 61000-6-2/-6-4 |
Safety | UL 508 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6 |
Declaration | |
Green Product | RoHS, CRoHS, WEEE |
MTBF | |
Time | ioLogik E2210 Series: 213,673 hrs ioLogik E2212 Series: 217,722 hrs ioLogik E2214 Series: 307,329 hrs ioLogik E2240 Series: 155,941 hrs ioLogik E2242 Series: 204,391 hrs ioLogik E2260 Series: 327,282 hrs ioLogik E2262 Series: 341,063 hrs |
Standards | Telcordia SR332 |
Warranty | |
Warranty Period | ioLogik E2214 Series: 2 years ioLogik E2210/E2212/E2240/E2242/E2260/E2262 Series: 5 years |
Details | See www.moxa.com/warranty |
Name | Type | Version | Release Date | |
Datasheet for ioLogik E2200 Series | Datasheet | V1.1 | 06 August 2020 |
Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/english/productview.php on line 615