Login   |  
Notice: Undefined index: basket in /opt/lampp/htdocs/english/menutop.php on line 14
(0)   |  

TEL. & FAX +66(0)2-020-3301

NPort S9650I Series

Home  >   MOXA  >   Industrial Edge Connectivity  >  
Serial Device Servers  >   Combo Device Servers

8/16-port rugged device server with managed Ethernet switch

Product Feature

  • Supports up to 4 managed Ethernet switch ports (fiber available with some optional network modules)
  • 8/16-port RS-232/422/485 serial interface
  • Supports DNP3 and Modbus protocols
  • Ethernet redundancy with Turbo Ring/Chain and RSTP/STP supported
  • Real COM/TTY drivers for Windows and Linux
  • IEC 61850-3, IEEE 1613 (power substations) compliant
  • IEEE 1588v2 and IRIG-B time synchronization functions
  • Supports IEC 61850 MMS protocol
  • Security features based on IEC 62443/NERC CIP
  • -40 to 85°C wide operating temperature

Introduction

The NPort S9650I Series 8/16-port RS-232/422/485 device servers, which come with a built-in full-function managed Ethernet switch, are designed specifically for the harsh environmental conditions found in electrical substations. With both fiber and wired Ethernet ports supported, the combination of a device server and Ethernet switch gives users the ability to easily install, manage, and maintain the NPort S9650I itself, as well as attached serial devices.

 

Electromagnetic Compatibility for Harsh Substation Environments

The NPort S9650I Series supports a high level of surge protection to prevent damage from the types of power surges and EMI one finds in electrical substations and industrial automation applications. Combined with a -40 to 85°C operating temperature range and galvanized steel housing, the NPort S9650I is suitable for a wide range of industrial environments.

Another plus is the NPort S9650I’s dual power supplies, which provide both redundancy, as well as a wide range of voltage inputs. The WV models accept a 24/48 VDC power input (ranging from 18 to 72 VDC), and the HV models accept a power input of 88 to 300 VDC and 85 to 264 VAC.

 

Power SCADA With IEC 61850 MMS for Easy Maintenance

The current trend in power SCADA applications is to control and monitor both IT devices (switches, routers, etc.) and IEDs (sensors, actuators, etc.) with the MMS protocol. Contrast this with the more traditional management approach of using SNMP for IT devices and MMS for IEDs. In fact, SIs may even need to manage a variety of legacy devices that use proprietary communications protocols.

The NPort S9650I device servers are the world’s first device servers to integrate MMS into an IT-type device designed specifically for power SCADA applications. The NPort S9650I even supports using MMS to monitor serial communications between the S9650I and legacy devices.

 

Supports Modbus/DNP3 Protocol Gateway

The NPort S9650I Series provides maximum flexibility for integrating industrial Modbus/DNP3 networks of all types and sizes. The NPort S9650I is designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master/slave combination, including simultaneous serial and Ethernet masters.

The NPort S9650I device servers also support protocol conversion between DNP3 serial and DNP3 IP, and all models are ruggedly constructed to ensure reliable operation.

 

Cybersecurity Features Based on IEC 62443/NERC CIP

The NPort S9650I Series has security features based on IEC 62443/NERC CIP to provide a high level of cybersecurity. Protecting mission-critical networks from cyberattacks is a high priority for industrial automation applications, which can suffer large losses due to extended network downtime.

 

Supports IEEE 1588v2 and IRIG-B Time Synchronization Functions

The NPort S9650I Series, which has a modular design that supports IEEE 1588v2 and IRIG-B time synchronization, is able to interconnect and synchronize multiple types of intelligent electronic devices (IEDs) that use different communication protocols. The time source is provided via IEEE 1588v2 and converted to IRIG-B for distribution to the IEDs via the serial ports or via a dedicated IRIG-B BNC connector.

 

Ring Redundancy at the Device Level

Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration to support the most demanding control applications. The NPort S9650I Series integrates a full-function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S9650I Series can achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.

Input/Output Interface

Alarm Contact ChannelsResistive load: 1 A @ 24 VDC

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector)NPort S9650I-E Series: 4 RJ45 ports
NPort S9650I-MSC Series: 2 RJ45 ports
NPort S9650I-SSC Series: 2 RJ45 ports
NPort S9650I-IRIG Series: 2 RJ45 ports
100BaseFX Ports (multi-mode SC connector)NPort S9650I-MSC Series: 2 multi-mode SC ports
100BaseFX Ports (single-mode SC connector)NPort S9650I-SSC Series: 2 single-mode SC ports
Magnetic Isolation Protection1.5 kV (built-in)
StandardsIEEE 802.1D-2004 for Spanning Tree Protocol
IEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for Rapid Spanning Tree Protocol
IEEE 802.1X for authentication
IEEE 802.3 for 10BaseT
IEEE 802.3ad for Port Trunk with LACP
IEEE 802.3u for 100BaseT(X) and 100BaseFX

Switch Properties

IGMP Groups256
Max. No. of VLANs64
Priority Queues4
VLAN ID RangeVID 1 to 4094

Ethernet Software Features

Configuration OptionsCommand Line Interface (CLI) through Serial/Telnet/SSH, Web Console
(HTTP/HTTPS), Windows Utility
ManagementDHCP Client, DHCP Option 82, HTTP, IEC 61850 MMS, IPv4, LLDP, Port Mirror,
RARP, RMON, SMTP, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Web Console
FilterGMRP, GVRP, IGMP v1/v2
Windows Real COM DriversWindows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10
(x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded
CE 5.0/6.0, Windows XP Embedded
Linux Real TTY DriversKernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x
Fixed TTY DriversSCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10,
FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X
Android APIAndroid 3.1.x and later
Industrial ProtocolsModbus TCP Server (Slave), DNP3 TCP Outstation
Time ManagementNTP Server/Client, SNTP, IEEE 1588v2 PTP (hardware-based), IRIG-B
MIBBridge MIB, Device Settings MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB,
Q-BRIDGE MIB, RFC1213, RFC1317, RMON MIB Groups 1, 2, 3, 9, RSTP MIB
Redundancy ProtocolsRSTP, Turbo Chain, Turbo Ring v1, Turbo Ring v2
SecurityHTTPS/SSL, Local Account Accessibility, TACACS+, RADIUS, SSH

IRIG-B Interface

PWM/PPS Output, BNC ConnectorNPort S9650I-IRIG Series: 1
PWM/PPS Output, DB9 FemaleNPort S9650I-8B-2HV-IRIG-T: 8
NPort S9650I-16B-2HV-IRIG-T: 16
PWM Input, BNC ConnectorNPort S9650I-IRIG Series: 1

Serial Interface

ConnectorNPort S9650I-8/-16 Series: DB9 male
NPort S9650I-8B/-16B Series: DB9 female
NPort S9650I-8F/-16F Series: Multi-mode fiber ST connector
No. of Ports8 or 16
Serial StandardsRS-232, RS-422, RS-485
Operation ModesReal COM mode, RFC2217 mode, TCP Client mode, TCP Server mode,
UDP mode, Modbus mode, DNP3 mode, DNP3 Raw Socket mode, Disabled
Baudrate50 bps to 921.6 kbps (supports non-standard baudrates)
Data Bits5, 6, 7, 8
Stop Bits1, 1.5, 2
ParityNone, Even, Odd, Space, Mark
Flow ControlNone, RTS/CTS, XON/XOFF
Isolation2 kV
Surge4 kV
RS-485 Data Direction ControlADDC® (automatic data direction control)
Pull High/Low Resistor for RS-4851 kilo-ohm, 150 kilo-ohms
Terminator for RS-485120 ohms
Console PortRS-232 (TxD, RxD, GND), 10-pin RJ45 (19200, n, 8, 1)

Serial Signals

RS-232NPort S9650I-IRIG Series: TxD, RxD, RTS, CTS, DTR/+IRIG-B, DSR, DCD, GND
NPort S9650I Series: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422NPort S9650I-IRIG Series: TxD+, TxD-, RxD+, RxD-, GND, +IRIG-B
NPort S9650I Series: Tx+, Tx-, Rx+, Rx-
RS-485-4wTx+, Tx-, Rx+, Rx-, GND
RS-485-2wNPort S9650I-IRIG Series: Data+, Data-, GND, +IRIG-B
NPort S9650I Series: Data+, Data-, GND

DIP Switch Configuration

Ethernet InterfaceTurbo Ring, Master, Coupler, Reserved

Modbus TCP

Max. No. of Client Connections32
Max. No. of Server Connections16

DNP3 (Transparent)

Max. No. of Master Connections16
Max. No. of Outstation Connections32

Reliability

Automatic Reboot TriggerBuilt-in WDT
Alert ToolsBuilt-in buzzer and RTC (real-time clock)

Power Parameters

No. of Power Inputs2
Reverse Polarity ProtectionSupported
Input Current0.65 A @ 100 VAC, 0.47A @ 100 VDC
Input Voltage110/220 VAC/VDC (100 to 240 VAC, 100 to 250 VDC)

Physical Characteristics

HousingMetal
Installation19-inch rack mounting
Dimensions457 x 32 x 330 mm (18 x 1.25 x 12.99 in)
WeightProduct only: 5.15 kg (11.35 lb)

Environmental Limits

Operating Temperature-40 to 85°C (-40 to 185°F)
Storage Temperature (package included)-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity5 to 95% (non-condensing)

Standards and Certifications

EMCEN 61000-6-2/-6-4
EMICISPR 32, FCC Part 15B Class A
EMSIEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11 DIPs
Environmental TestingIEC 60068-2-2
IEC 60068-2-14
Power SubstationIEC 61850-3, IEEE 1613
SafetyEN 61010-2-201, UL 61010-2-201
ShockIEC 60068-2-27
VibrationIEC 60068-2-6, IEC 60068-2-64

Declaration

Green ProductRoHS, CRoHS, WEEE

MTBF

TimeNPort S9650I-8-2HV-E-T: 224,670 hrs
NPort S9650I-8-2HV-MSC-T: 220,944 hrs
NPort S9650I-8-2HV-SSC-T: 220,944 hrs
NPort S9650I-8B-2HV-IRIG-T: 213,025 hrs
NPort S9650I-8F-2HV-E-T: 311,734 hrs
NPort S9650I-8F-2HV-MSC-T: 304,587 hrs
NPort S9650I-8F-2HV-SSC-T: 304,587 hrs
NPort S9650I-16-2HV-E-T: 158,816 hrs
NPort S9650I-16-2HV-MSC-T: 156,949 hrs
NPort S9650I-16-2HV-SSC-T: 156,949 hrs
NPort S9650I-16B-2HV-IRIG-T: 157,770 hrs
NPort S9650I-16F-2HV-E-T: 261,817 hrs
NPort S9650I-16F-2HV-MSC-T: 256,761 hrs
NPort S9650I-16F-2HV-SSC-T: 256,761 hrs
StandardsTelcordia SR332

Warranty

Warranty Period5 years
DetailsSee www.moxa.com/warranty
Name Type Version Release Date
Datasheet for NPort S9650I Series Datasheet V1.2 16 December 2019

Notice: Undefined variable: rs5 in /opt/lampp/htdocs/english/productview.php on line 609

Notice: Trying to get property 'tab_ap' of non-object in /opt/lampp/htdocs/english/productview.php on line 609


Notice: Undefined variable: title_ap in /opt/lampp/htdocs/english/productview.php on line 614


Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/english/productview.php on line 615

PT AUTOMATION (THAILAND) CO.,LTD.

Monday - Friday : office hours 9.00 AM – 6.00 PM

EN
TH