The NPort S9650I Series 8/16-port RS-232/422/485 device servers, which come with a built-in full-function managed Ethernet switch, are designed specifically for the harsh environmental conditions found in electrical substations. With both fiber and wired Ethernet ports supported, the combination of a device server and Ethernet switch gives users the ability to easily install, manage, and maintain the NPort S9650I itself, as well as attached serial devices.
The NPort S9650I Series supports a high level of surge protection to prevent damage from the types of power surges and EMI one finds in electrical substations and industrial automation applications. Combined with a -40 to 85°C operating temperature range and galvanized steel housing, the NPort S9650I is suitable for a wide range of industrial environments.
Another plus is the NPort S9650I’s dual power supplies, which provide both redundancy, as well as a wide range of voltage inputs. The WV models accept a 24/48 VDC power input (ranging from 18 to 72 VDC), and the HV models accept a power input of 88 to 300 VDC and 85 to 264 VAC.
The current trend in power SCADA applications is to control and monitor both IT devices (switches, routers, etc.) and IEDs (sensors, actuators, etc.) with the MMS protocol. Contrast this with the more traditional management approach of using SNMP for IT devices and MMS for IEDs. In fact, SIs may even need to manage a variety of legacy devices that use proprietary communications protocols.
The NPort S9650I device servers are the world’s first device servers to integrate MMS into an IT-type device designed specifically for power SCADA applications. The NPort S9650I even supports using MMS to monitor serial communications between the S9650I and legacy devices.
The NPort S9650I Series provides maximum flexibility for integrating industrial Modbus/DNP3 networks of all types and sizes. The NPort S9650I is designed to integrate Modbus TCP, ASCII, and RTU devices in almost any master/slave combination, including simultaneous serial and Ethernet masters.
The NPort S9650I device servers also support protocol conversion between DNP3 serial and DNP3 IP, and all models are ruggedly constructed to ensure reliable operation.
The NPort S9650I Series has security features based on IEC 62443/NERC CIP to provide a high level of cybersecurity. Protecting mission-critical networks from cyberattacks is a high priority for industrial automation applications, which can suffer large losses due to extended network downtime.
The NPort S9650I Series, which has a modular design that supports IEEE 1588v2 and IRIG-B time synchronization, is able to interconnect and synchronize multiple types of intelligent electronic devices (IEDs) that use different communication protocols. The time source is provided via IEEE 1588v2 and converted to IRIG-B for distribution to the IEDs via the serial ports or via a dedicated IRIG-B BNC connector.
Device-level communication networks for industrial automation are very critical since they are used to control and monitor device processes. The reliability of these communications depends on ring redundancy at the device level, which is designed to provide fast network fault detection and reconfiguration to support the most demanding control applications. The NPort S9650I Series integrates a full-function NPort device server with an industrial switch to carry serial and Ethernet devices at the same time. In addition, the NPort S9650I Series can achieve ring redundancy with standard STP/RSTP and Moxa’s proprietary Turbo Ring or Turbo Chain 2 redundancy protocols. This all-in-one design can be used to optimize and simplify your device network and enhance reliability.
Input/Output Interface | |
Alarm Contact Channels | Resistive load: 1 A @ 24 VDC |
Ethernet Interface | |
10/100BaseT(X) Ports (RJ45 connector) | NPort S9650I-E Series: 4 RJ45 ports NPort S9650I-MSC Series: 2 RJ45 ports NPort S9650I-SSC Series: 2 RJ45 ports NPort S9650I-IRIG Series: 2 RJ45 ports |
100BaseFX Ports (multi-mode SC connector) | NPort S9650I-MSC Series: 2 multi-mode SC ports |
100BaseFX Ports (single-mode SC connector) | NPort S9650I-SSC Series: 2 single-mode SC ports |
Magnetic Isolation Protection | 1.5 kV (built-in) |
Standards | IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1p for Class of Service IEEE 802.1Q for VLAN Tagging IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1X for authentication IEEE 802.3 for 10BaseT IEEE 802.3ad for Port Trunk with LACP IEEE 802.3u for 100BaseT(X) and 100BaseFX |
Switch Properties | |
IGMP Groups | 256 |
Max. No. of VLANs | 64 |
Priority Queues | 4 |
VLAN ID Range | VID 1 to 4094 |
Ethernet Software Features | |
Configuration Options | Command Line Interface (CLI) through Serial/Telnet/SSH, Web Console (HTTP/HTTPS), Windows Utility |
Management | DHCP Client, DHCP Option 82, HTTP, IEC 61850 MMS, IPv4, LLDP, Port Mirror, RARP, RMON, SMTP, SNMPv1/v2c/v3, Syslog, Telnet, TFTP, Web Console |
Filter | GMRP, GVRP, IGMP v1/v2 |
Windows Real COM Drivers | Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64), Windows 2008 R2/2012/2012 R2 (x64), Windows Embedded CE 5.0/6.0, Windows XP Embedded |
Linux Real TTY Drivers | Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x |
Fixed TTY Drivers | SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10, FreeBSD, AIX 5.x, HP-UX 11i, Mac OS X |
Android API | Android 3.1.x and later |
Industrial Protocols | Modbus TCP Server (Slave), DNP3 TCP Outstation |
Time Management | NTP Server/Client, SNTP, IEEE 1588v2 PTP (hardware-based), IRIG-B |
MIB | Bridge MIB, Device Settings MIB, Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RFC1213, RFC1317, RMON MIB Groups 1, 2, 3, 9, RSTP MIB |
Redundancy Protocols | RSTP, Turbo Chain, Turbo Ring v1, Turbo Ring v2 |
Security | HTTPS/SSL, Local Account Accessibility, TACACS+, RADIUS, SSH |
IRIG-B Interface | |
PWM/PPS Output, BNC Connector | NPort S9650I-IRIG Series: 1 |
PWM/PPS Output, DB9 Female | NPort S9650I-8B-2HV-IRIG-T: 8 NPort S9650I-16B-2HV-IRIG-T: 16 |
PWM Input, BNC Connector | NPort S9650I-IRIG Series: 1 |
Serial Interface | |
Connector | NPort S9650I-8/-16 Series: DB9 male NPort S9650I-8B/-16B Series: DB9 female NPort S9650I-8F/-16F Series: Multi-mode fiber ST connector |
No. of Ports | 8 or 16 |
Serial Standards | RS-232, RS-422, RS-485 |
Operation Modes | Real COM mode, RFC2217 mode, TCP Client mode, TCP Server mode, UDP mode, Modbus mode, DNP3 mode, DNP3 Raw Socket mode, Disabled |
Baudrate | 50 bps to 921.6 kbps (supports non-standard baudrates) |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 1.5, 2 |
Parity | None, Even, Odd, Space, Mark |
Flow Control | None, RTS/CTS, XON/XOFF |
Isolation | 2 kV |
Surge | 4 kV |
RS-485 Data Direction Control | ADDC® (automatic data direction control) |
Pull High/Low Resistor for RS-485 | 1 kilo-ohm, 150 kilo-ohms |
Terminator for RS-485 | 120 ohms |
Console Port | RS-232 (TxD, RxD, GND), 10-pin RJ45 (19200, n, 8, 1) |
Serial Signals | |
RS-232 | NPort S9650I-IRIG Series: TxD, RxD, RTS, CTS, DTR/+IRIG-B, DSR, DCD, GND NPort S9650I Series: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
RS-422 | NPort S9650I-IRIG Series: TxD+, TxD-, RxD+, RxD-, GND, +IRIG-B NPort S9650I Series: Tx+, Tx-, Rx+, Rx- |
RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND |
RS-485-2w | NPort S9650I-IRIG Series: Data+, Data-, GND, +IRIG-B NPort S9650I Series: Data+, Data-, GND |
DIP Switch Configuration | |
Ethernet Interface | Turbo Ring, Master, Coupler, Reserved |
Modbus TCP | |
Max. No. of Client Connections | 32 |
Max. No. of Server Connections | 16 |
DNP3 (Transparent) | |
Max. No. of Master Connections | 16 |
Max. No. of Outstation Connections | 32 |
Reliability | |
Automatic Reboot Trigger | Built-in WDT |
Alert Tools | Built-in buzzer and RTC (real-time clock) |
Power Parameters | |
No. of Power Inputs | 2 |
Reverse Polarity Protection | Supported |
Input Current | 0.65 A @ 100 VAC, 0.47A @ 100 VDC |
Input Voltage | 110/220 VAC/VDC (100 to 240 VAC, 100 to 250 VDC) |
Physical Characteristics | |
Housing | Metal |
Installation | 19-inch rack mounting |
Dimensions | 457 x 32 x 330 mm (18 x 1.25 x 12.99 in) |
Weight | Product only: 5.15 kg (11.35 lb) |
Environmental Limits | |
Operating Temperature | -40 to 85°C (-40 to 185°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | |
EMC | EN 61000-6-2/-6-4 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m; Signal: 10 V/m IEC 61000-4-8 PFMF IEC 61000-4-11 DIPs |
Environmental Testing | IEC 60068-2-2 IEC 60068-2-14 |
Power Substation | IEC 61850-3, IEEE 1613 |
Safety | EN 61010-2-201, UL 61010-2-201 |
Shock | IEC 60068-2-27 |
Vibration | IEC 60068-2-6, IEC 60068-2-64 |
Declaration | |
Green Product | RoHS, CRoHS, WEEE |
MTBF | |
Time | NPort S9650I-8-2HV-E-T: 224,670 hrs NPort S9650I-8-2HV-MSC-T: 220,944 hrs NPort S9650I-8-2HV-SSC-T: 220,944 hrs NPort S9650I-8B-2HV-IRIG-T: 213,025 hrs NPort S9650I-8F-2HV-E-T: 311,734 hrs NPort S9650I-8F-2HV-MSC-T: 304,587 hrs NPort S9650I-8F-2HV-SSC-T: 304,587 hrs NPort S9650I-16-2HV-E-T: 158,816 hrs NPort S9650I-16-2HV-MSC-T: 156,949 hrs NPort S9650I-16-2HV-SSC-T: 156,949 hrs NPort S9650I-16B-2HV-IRIG-T: 157,770 hrs NPort S9650I-16F-2HV-E-T: 261,817 hrs NPort S9650I-16F-2HV-MSC-T: 256,761 hrs NPort S9650I-16F-2HV-SSC-T: 256,761 hrs |
Standards | Telcordia SR332 |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Name | Type | Version | Release Date | |
Datasheet for NPort S9650I Series | Datasheet | V1.2 | 16 December 2019 |
No. of Serial Ports | 8 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 4 x RJ45 |
No. of Serial Ports | 8 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 8 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 8 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | ✓ |
No. of Ethernet Ports | 2 |
Ethernet Port Connector | 2 x RJ45 |
No. of Serial Ports | 8 |
Serial Port Connector | Multi-mode ST fiber |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 4 x RJ45 |
No. of Serial Ports | 8 |
Serial Port Connector | Multi-mode ST fiber |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 8 |
Serial Port Connector | Multi-mode ST fiber |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 16 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 4 x RJ45 |
No. of Serial Ports | 16 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 16 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 16 |
Serial Port Connector | DB9 male |
IRIG-B Time Sync | ✓ |
No. of Ethernet Ports | 2 |
Ethernet Port Connector | 2 x RJ45 |
No. of Serial Ports | 16 |
Serial Port Connector | Multi-mode ST fiber |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 4 x RJ45 |
No. of Serial Ports | 16 |
Serial Port Connector | Multi-mode ST fiber |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
No. of Serial Ports | 16 |
Serial Port Connector | Multi-mode ST fiber |
IRIG-B Time Sync | – |
No. of Ethernet Ports | 4 |
Ethernet Port Connector | 2 x RJ45, 2 x multi-mode SC fiber |
Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/productview.php on line 639