Output Voltage
24V
Output Power
30W
Output Current
1.25A
Input Voltage Range
85-264Vac
Dimensions (L x W x D)
75 x 21 x 89.5 mm
2.95” x 0.83” x 3.52”
Unit Weight
0.11 kg (0.24 lb)
Output Current 1.25A |
Output Voltage 24V |
Output Voltage Adjustment Range 24-28Vdc |
Output Power 30W |
Line Regulation < 0.5% (@ 85-264Vac, 100% load) |
Load Regulation < 1.0% (@ 85-264Vac, 0-100% load) |
PARD < 75mVpp @ > 0°C to 70°C |
Start-up Time < 2,500ms @ 115Vac (100% load) |
Hold-up Time > 20ms @ 115Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage) ± 5% @ 85-264Vac input, 0-100% load |
Start-up with Capacitive Loads 3,000μF Max |
Input Voltage 100-240Vac |
Input Voltage Range 85-264Vac |
Nominal Input Frequency 50-60Hz |
Input Frequency Range 47-63Hz |
DC Input Voltage Range 120-375Vdc |
Input Current < 0.55A @ 115Vac, < 0.35A @ 230Vac |
Efficiency at 100% load > 87.5% @ 115Vac, > 88.0% @ 230Vac |
Max Inrush Current < 20A @ 115Vac, < 40A @ 230Vac |
Leakage Current IEC/EN 60950-1: < 0.5mA @ 264Vac |
Max Power Dissipation 0% load: < 0.5W @ 115Vac & 230Vac |
Case Chassis / Cover Plastic | |
Indicator Green LED: DC OK | |
Cooling System Convection | |
Unit Weight 0.11 kg (0.24 lb) | Dimensions 75 x 21 x 89.5 mm |
Vibration (Operating) IEC 60068-2-6, Sine Wave: 10-500Hz; 2G peak; displacement of 0.35mm; 1 octave per min; 60 min per axis for all X, Y, Z directions |
Shock Test (Operating) IEC 60068-2-27, Half Sine Wave: 10G for a duration of 11ms; |
Operating Temperature -20°C to +70°C (Cold start at -40°C @ 40% load) |
Storage Temperature -40°C to +85°C |
Power De-rating Temperature: -10°C to -20°C de-rate power by 2% / °C |
Operating Humidity 5 to 95% RH (Non-Condensing) |
Shock Test (Non-Operating) IEC60068-2-27, Half Sine Wave: 50G for a duration of 11ms; |
Vibration (Non-Operating) IEC 60068-2-6, Random: 5-500Hz; 2.09Grms, 20 min per axis for all X, Y, Z directions |
Over Voltage Category II |
Overvoltage < 34.8V, SELV Output, Latch Mode |
Overload / Overcurrent 105~140% of rated load current, Foldback Mode (continuous current, voltage drops), Auto-recovery when the fault is removed |
Over Temperature < 75°C Surrounding Air Temperature @ 100% load, Latch Mode |
Short Circuit Hiccup Mode, Non-Latching (Auto-recovery when the fault is removed) |
Degree of Protection IP20 |
Protection Against Shock Class I with PE connection |
MTBF > 700,000 hrs. as per Telcordia SR-332 |
Electrical Safety TUV Bauart: EN 60950-1, EN 62368-1 |
CE In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
Galvanic Isolation Input to Output: 3.0 KVac |
Industrial Control Equipment UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E315335) |
Safety Entry Low Voltage SELV (EN 60950) |
Material and Parts RoHS Directive 2011/65/EU Compliant |
Emission (CE & RE) |
Immunity Generic Standards: EN 55024, EN 61000-6-1, EN 61000-6-2 |
Harmonic Current Emissions IEC/EN 61000-3-2, Class A |
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 |
Component Power Supply for General Use EN 61204-3 |
Name | Type | Version | Release Date | |
Datasheet | Datasheet | V1.0 | 22 April 2020 |