TEL. & FAX +66(0)2-020-3301

PJ-24V30W

Home  >   Delta PSU  >   Open Frame Power Supply  >  
PJ

Open Frame PJ Series

Product Feature

  • Universal AC input voltage range
  • Low Inrush Current / Low Leakage Current
  • High efficiency
  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Conformal coating on PCBA to protect against chemical and dust pollutants
  • Versatile configuration options: Open Frame, L Frame, Enclosed
  • Long life capacitors


 

Output Voltage

 

24V

Output Power

 

31W

Output Current

 

1.3A

Input Voltage Range

 

85-264Vac

Dimensions (L x W x H)

 

105 x 50 x 25.6 mm (Open Frame)
125 x 60 x 36 mm (Enclosed)
4.13" x 1.96" x 1.00” (Open Frame)
4.92" x 2.36" x 1.41" (Enclosed)

Unit Weight

 

0.11 kg (Open Frame)<br>0.20 kg (Enclosed) (0.24 lb)

Output Current

1.3A

Output Voltage

24V

Output Voltage Adjustment Range

21.6-26.4Vdc

Output Power

31W

Line Regulation

< 96mV

Load Regulation

< 150mV

Start-up Time

500ms typ. @ 100Vac

Hold-up Time

20ms Typ. @ 100Vac

Dynamic Response (Overshoot & Undershoot O/P Voltage)

± 5% @ 0-50% load and 50-100% load

Start-up with Capacitive Loads

8,000µF Max

Residual Ripple/PARD (20MHz)

< 120mVpp @ 0°C to 50°C,
< 160mVpp @ -10°C to 0°C

Ripple & Noise

< 150mVpp @ 0°C to 50°C,
< 180mVpp @ -10°C to 0°C

Input Voltage

100-240Vac

Input Voltage Range

85-264Vac

Nominal Input Frequency

50-60Hz

Input Frequency Range

47-63Hz

Input Current

0.65Atyp. @100Vac,
0.35Atyp. @ 200Vac

Efficiency at 100% load

85.0% typ. @ 100Vac,
86.0% typ. @ 200Vac

Max Inrush Current

15A typ. @ 100Vac,
30A typ. @ 200Vac

Leakage Current

0.1mA @ 100Vac,
0.2mA @ 230Vac

 

Case Chassis / Cover

SGCC

 

Cooling System

Convection

 

Input/Output Terminal

JST B3P5-VH (LF)(SN)

 

Signal

JST B4P-VH (LF)(SN)

 

Wire

AWG 22-18

 

Unit Weight

0.11 kg (Open Frame)<br>0.20 kg (Enclosed) (0.24 lb)

Dimensions

105 x 50 x 25.6 mm (Open Frame)
125 x 60 x 36 mm (Enclosed)
4.13" x 1.96" x 1.00” (Open Frame)
4.92" x 2.36" x 1.41" (Enclosed)

Operating Temperature

-10°C to +70°C

Storage Temperature

-25°C to +75°C

Power De-rating

>50°C de-rate power by 2.5% /°C, <90Vac de-rate power by 2%/V

Operating Humidity

5 to 95% RH (Non-Condensing)

Shock Test (Non-Operating)

IEC60068-2-27,196.1m/S² (20G), 11ms, once along X, Y, and Z axis

Vibration (Non-Operating)

IEC60068-2-6, 10Hz to 55Hz@19.6m/S² (2G); 3min period, 60 min per axis for all X, Y, Z direction

Overvoltage

27.6-33.6V, Latch Mode

Overload / Overcurrent

> 105% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)

Over Temperature

Latch Mode

Short Circuit

Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)

Protection Against Shock

Class I with Primary Earth connection

MTBF

> 200,000 hrs. as per JEITA RCR-9102B

Expected Cap Life Time

10 years (115Vac, 50% load @ 40°C)


Electrical Safety

TUV Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E131881), UL 62368-1 and CSA C22.2 No. 62368-1 (File No. E131881)
CB scheme : IEC 60950-1, IEC 62368-1

CE

In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU

Galvanic Isolation

Input to Output: 3.0 KVac
Input to Ground: 2.0 KVac
Output to Ground: 0.5 KVac

Emission

CISPR 32, EN 55032, FCC Title 47: Class B

Harmonic Current Emissions

IEC/EN 61000-3-2, Class A

Voltage Fluctuation and Flicker

IEC/EN 61000-3-3

 

Name Type Version Release Date
PJ-24V30W Datasheet 1.0 25 January 2021
PJ-24V30W Manual 1.0 25 January 2021

บริษัท พีที ออโตเมชั่น (ไทยแลนด์) จำกัด

จันทร์ ถึง ศุกร์ เวลา 9.00 น. – 18.00 น.

EN