The ICF-1170I Series CAN-to-fiber converters are used to convert CAN signals from copper to optical fiber. The converters come with 2 kV optical isolation for the CAN bus system and dual power inputs with alarm contact relay to ensure that your CAN bus system will remain online.
Fiber Test Mode can be used to test the fiber cable between two ICF-1170I units, and it provides a simple way to determine if the fiber cable is transmitting data correctly. When in Fiber Test Mode, the fiber transceiver (Tx) will continuously send out a data signal and the Fiber Tx LED will light up. On the other side of the connection, when the ICF-1170I fiber transceiver (Rx) receives the data signal from the Tx side, the Fiber Rx LED will light up.
Serial Interface | |
Optical Fiber | ICF-1170I-M-ST: 100BaseFX ports (multi-mode ST connector) |
Optical Fiber | Read more |
CAN Interface | |
Isolation | 2 kV (built-in) |
No. of Ports | 1 |
Signals | CAN_L, CAN_H, CAN Signal GND |
Terminator | N/A, 120 ohms (by DIP) |
Power Parameters | |
Input Current | 221 mA @ 12 to 48 VDC |
Power Consumption | 221 mA @ 12 to 48 VDC |
Input Voltage | 12 to 48 VDC |
No. of Power Inputs | 2 |
Overload Current Protection | Supported |
Power Connector | Terminal block (for DC models) |
Physical Characteristics | |
Housing | Metal |
IP Rating | IP30 |
Dimensions | 30.3 x 70 x 115 mm (1.19 x 2.76 x 4.53 in) |
Weight | 178 g (0.39 lb) |
Installation | DIN-rail mounting |
Environmental Limits | |
Operating Temperature | ICF-1170I-M-ST: 0 to 60°C (32 to 140°F) ICF-1170I-M-ST-T: -40 to 85°C (-40 to 185°F) |
Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Standards and Certifications | |
EMC | EN 55032/24 |
EMI | CISPR 32, FCC Part 15B Class A |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 1 kV IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m IEC 61000-4-8 PFMF |
Environmental Testing | IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-3 |
Safety | EN 60950-1, IEC 60950-1 |
Vibration | IEC 60068-2-6 |
MTBF | |
Time | 792,085 hrs |
Standards | Telcordia (Bellcore), GB |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |
Name | Type | Version | Release Date | |
Datasheet for ICF-1170I Series | Datasheet | V1.1 | 08 May 2020 |
Operating Temp. | 0 to 60°C |
Operating Temp. | -40 to 85°C |
Notice: Undefined variable: detail_ap in /opt/lampp/htdocs/productview.php on line 639